ASD500開關柜綜合測控裝置
1安裝使用指南
1 Installation and operation guide
1.1產品概述
1.1 Product overview
ASD500開關柜綜合測控裝置用于3~35kV戶內開關柜,適用于中置柜、手車柜、固定柜、環(huán)網柜等多種開關柜。具有一次回路模擬圖及開關狀態(tài)指示,高壓帶電顯示及核相,自動溫濕度控制,加熱回路故障告警,分合閘回路完好指示、分合閘回路電壓測量、預分預合閃光指示、電氣節(jié)點無線測溫,人體感應自動照明,語音提示,電參數測量及RS485通訊接口等眾多功能,集操作、顯示于一體。
ASD series switch cabinet integrated measuring and control device is used for 3-35kV indoor switch cabinet, Applying to centrally installed switchgear, trolley cabinet, fixed switchgear, ring main unit and other various switch cabinets. With primary circuit mimetic diagram and switch status indicator, HV live displaying and nuclear phase, automatic temperature and humidity control, heating circuit fault alarm, wireless temperature measurement, tripping circuit and closing circuit supervising, tripping circuit and closing circuit control voltage measurement, pre-tripping circuit and pre-closing indication,body induction auto lighting, voice prompt, electrical parameter measurement and RS485 communication interface and other numerous functions, it has integrated operation and display into one.
1.2型號說明
1.2 Description of types
圖1.1 ASD系列產品命名規(guī)則
Figure1.1 ASD Series Product naming rule
1.3產品型號及功能
1.3 Product model and function
表1 ASD500產品型號及功能
Table1 ASD 500 Product specification and functions
型號Type
功能項
function
ASD500
產品圖片
Product picture
開孔尺寸
Cut-out dimensions
220mm×165mm
一次模擬圖
Primary circuit analog chart
標配
Standard
帶電顯示及自檢/核相
Live display and self-test/nuclear phase
標配
Standard
電磁閉鎖出口
Electromagnetic lockout outle
一路
Configuration 1
溫濕度控制
Temp./humidity control
標配1路傳感器,線長4米
Standard 1 sensor,line lengh 4meters
三路加熱,一路鼓風
Three heating,One blowing
強制加熱
Forced heating
標配
Standard
加熱回路故障告警
Heating circuitFault alarm
標配
Standard
斷電告警
Power off alarm
標配
Standard
語音提示
Voice prompts
標配
Standard
人體感應探頭
Sensing probe for humanbody
標配
Standard
操作旋鈕
Operating knob
可選
Optional
斷路器分合次數顯示
Beaker frequency shows
標配
Standard
預分預合閃光指示
pre-tripping circuit and pre-closing indication
可選
Optional
(該功能僅限于配有帶預分、預合功能的操作開關裝置)
(This function only takes effect when there is a pre-tripping circuit and pre-closing indication switch)
分閘、合閘完好指示tripping circuit and closing circuit supervising,
標配
Standard
分合閘回路電壓測量
tripping circuit and closing circuit control voltage measurement
標配
Standard
無線測溫
Wireless temperature measurement
可選
Optional
主回路電力參數測量
Measure and display of power parameter
標配
Standard
RS485通訊接口 Communication port
標配
Standard
1.4技術指標
1.4 Technical indexes
表2 ASD500技術指標
Table2 ASD SeriesTechnical data
項目
Item
指標 Value
ASD500
額定輸入
Rated input
接線方式
Wiring mode
3P3L或3P4L
3P3L or3P4L
電壓
Voltage
100V
電流
Current
5A
頻率
frequency
50Hz
準確度
Accuracy rating
電流、電壓
Current、Voltage
0.5級
0.5 class
有功功率、無功功率
Active power、
Reactive power
電能
Energy
分合閘回路電壓
tripping circuit and closing circuit control voltage
1級
1 class
環(huán)境溫度
Environment temperature
±1℃
相對濕度
Relative humidity
±5%
裝置工作電源
Device Working power
AC 85~265V,DC 100~300V
功耗
Power consumption
輔助電源
Auxiliary power
≤8VA
電壓輸入
Voltage input
≤0.5VA
電流輸入
Current input
≤1VA
通訊
Communication
協議
protocol
MODBUS-RTU、MODBUS-TCP
波特率(bps)
Baud rate(bps)
2400、4800、9600、19200
無線測溫
Wireless temperature measurement
測溫范圍Temperature measurement range
-50℃~+125℃
測溫精度
Temperature measurement accuracy
±1℃
傳感器電池壽命
Sensor battery life
≥5年
≥5 year
傳感器啟動電流
starting current
≥5A
環(huán)境要求
Environmental
requirement
工作溫度
Operating temperature
-10℃~55℃
相對濕度
Relative humidity
≤95%
平均無故障工作時間
Average work time without stoppage
≥50000小時
≥50000hour

1.5產品安裝
1.5 Product installation
ASD500開關柜綜合測控裝置采用面板嵌入式安裝,首先柜體盤面上制作規(guī)定尺寸的長方形槽孔,裝置取下支架后嵌入槽孔,再用支架固定即可。
Panel embedded installation is adopted for ASD series switch cabinet integrated measuring and control device: firstly fabricate rectangular slot with stipulated size on cabinet face; embed the device into the slot after taking down the support and then fix by support.
1.5.1安裝方法
1.5.1 Installation method

圖1.2 ASD500安裝方法
Figure 1.2 Installation method of ASD500
1.5.2開孔尺寸(單位:毫米)
1.5.2 Hole size (unit: mm)
圖1.3 ASD500開孔尺寸
Figure 1.3Hole size diagram of ASD500
1.5.3溫濕度傳感器、無線溫度收發(fā)器的安裝
1.5.3 Installation of temperature and humidity sensor, wireless temperature transceiver
與ASD500產品配套使用的溫濕度傳感器和無線測溫接收器,可以采用導軌(DIN35mm)安裝方式,也可以使用螺栓固定方式,如圖1.4所示。
The temperature and humidity sensor and wireless temperature transceiver used as ancillary with ASD500 products can adopt guide rail (DIN35mm) installation or bolt fixing, as shown in Figure 1.4.


圖1.4 溫濕度傳感器和無線溫度收發(fā)器安裝方式
Figure 1.7 Installation methods of temperature and humidity sensor and wireless temperature transceiver
1.5.4無線溫度傳感器的安裝
1.5.4 Installation of wireless temperature transceiver
無線溫度傳感器共有多種型號,分別對應螺栓固定、表帶固定、扎帶捆綁、合金片固定等安裝方式。
There are several types of wireless temperature sensors and mounting methods correspondingly, i.e. bolted type, strap-secured type, tied type and alloy chip fixed type.
Parameter Type
wireless temperature sensors
ATE100M
ATE100
ATE200
ATE400
Power supply
Battery
CT inductive powered
Wireless frequency
470MHz
470MHz
Sampling frequency
25s
15s
Transmission
frequency
25s-5min
15s
Range of temperature
-50℃~+125℃
Accuracy
±1℃
Transmission
distance
150m in open area
Sevice life
>5 years(battery life)
>10 years
Installation
Magnetic
Bolted
Belt
Tied with cable tie
Application
between bus bar and cable joints
Bus bar, cable joints and fixed contact

圖1.5表帶式無線溫度傳感器ATE200
Figure 1.5Strap-secured wireless temperature sensor ATE200


圖1.6螺栓式無線溫度傳感器ATE100 圖1.7磁吸式無線溫度傳感器ATE100M
Figure 1.6 Bolt wireless temperature sensorATE100Figure 1.7Magnetic wireless temperature sensorATE100M
圖1.8無源無線溫度傳感器ATE400
Figure1.8Passive wireless temperature sensorATE400
迷你型無源無線溫度傳感器結構說明:
Mini type passive temperaturesensor structure introduction:
1——溫度傳感器主體The core of wireless temperature sensor ATE400
2——合金底座,與溫度探頭接觸alloy bottom, touched with temperature probe
3 ——鎖扣,用于固定合金片metal hasp, for fixing alloy chip
4——取電合金片,用于感應取電alloy chip, for CT-powered
5 ——硅膠墊片,用于支撐合金片silicone gasket, used to support the alloy chip
6 ——合金片安裝孔,用于安裝合金片alloy chip hole, usedto install the alloy chip
圖1.9 ATE400結構說明
Figure1.9 structure introduction of ATE400
1.6接線方法
1.6 Wiring method
1.6.1接線端子
1.6.1 Wiring terminal

圖1.10 ASD500背面端子圖
Figure 1.10 ASD500 back terminal diagram
1.6.2典型接線圖
1.6.2 Typical wiring diagram

圖1.11 ASD開關量輸入回路典型接線圖
Figure 1.11 Typical wiring diagram of ASD switch input circuit

圖1.12 ASD開關量輸出、高壓帶電顯示回路及傳感器典型接線圖
Figure 1.19 Typical wiring diagram of ASD switch output, HV live displaying circuit and sensor
2界面簡介
2.1 主界面說明
裝置上電即顯示主界面,點擊屏幕上半部分,進入“電量”、“溫濕”、“節(jié)溫”的參數界面,如圖2.1-1~2.1-2所示,可通過點擊導航欄,切換界面。
圖2.1-1 圖2.1-2

圖2.1-3 圖2.1-4
2.2事件界面說明
點擊導航欄內的事件菜單欄,可最多查詢50條告警記錄,圖2.2-1和50條故障記錄,如圖2.2-2。
圖2.2-1 圖2.2-2
2.3參數界面說明
點擊導航欄內的參數菜單欄,進入輸密碼界面,密碼為“8”,可在其子菜單欄內查看“通訊”、“時間”、“電力”、“溫濕”、“節(jié)溫”、“變送”、“繼電”、“語音”、“狀態(tài)”、“動作”、“分合閘”、“清除”的參數界面。
圖2.3-1 圖2.3-2 圖2.3-3
圖2.3-4 圖2.3-5 圖2.3-6
2.4調試界面說明
點擊導航欄內的參數菜單欄,可在其子菜單欄內查看“I/O”、“斷路器”、“信息”的參數界面;按子菜單欄的右翻鍵,輸入密碼“1008”,進入“電量校準”、“設置”、“節(jié)溫校準”的參數界面。
圖2.4-1 圖2.4-2 圖2.4-3
3產品操作指南
3 Product operation guide
本操作說明主要針對ASD500型開關柜綜合測控裝置。
The operation instruction mainly aims at ASD300 switch cabinet integrated measuring and control device.
3.1顯示介紹
3.1 Display introduction
3
4
5
1
6
6
7
2
圖3.1 ASD500前面板圖
Figure 3.1 ASD500 front panel diagram
表3 ASD500前面板功能說明
Table 3 Function description of ASD500 front panel
編號
No.
說明
Description
1
液晶顯示屏
LCD
2
遠方/就地操作開關
Remote/local operating switch
3
語音提示
Voice prompt
4
人體感應探測口
Human body induction detection port
5
儲能旋鈕
Stored energy knob
6
分閘/合閘操作開關
Tripping/closing operating switch
7
高壓帶電顯示及閉鎖
HV live displaying and lock
3.2操作介紹
3.2 Operation introduction
3.2.1裝置上電
3.2.1 Device power-on
接通符合要求的工作電源,裝置即進入工作狀態(tài)。
Connect the working power supply conforming to requirements and the device will enter working state.
3.2.2動態(tài)模擬圖
3.2.2 Dynamic mimetic diagram
1)斷路器分、合閘指示
1) Breaker tripping/closing instructions
將斷路器的分、合位置的輔助接點正確接入裝置,裝置上電正常工作后:
After the auxiliary contact of breaker tripping/closing position is correctly connected to device and the device is powered on for normal operation:
斷路器處于合閘狀態(tài)時,紅色發(fā)光條3亮;
When the breaker is under close position, the red light bar 3 will be on;
斷路器處于分閘狀態(tài)時,綠色發(fā)光條4亮;
When the breaker is under open position, the green light bar 4 will be on;
2)手車位置指示
2) Trolley position instructions:
將手車位置的輔助接點正確接入裝置,裝置上電正常工作后:
After the auxiliary contact of trolley position is correctly connected to device and the device is powered on for normal operation:
手車工作位置接點閉合時,紅色發(fā)光條1、5(上下兩條)亮,指示小車位于工作位置;
When the operating position contact of trolley is closed, the red light bar 1、bar5 (upper and lower ones) will be on and it indicates that the trolley is under operating position;
手車試驗位置接點閉合時,綠色發(fā)光條2、6(上下兩條)亮,指示小車位于試驗位置。
When the testing position contact of trolley is closed, the green light bar 2、 bar 6 (upper and lower ones) will be on and it indicates that the trolley is under testing position.
3)接地開關位置指示
3) Earthing switch position instructions
將接地開關的輔助接點正確接入裝置,裝置上電正常工作后:
After the auxiliary contact of trolley position is correctly connected to device and the device is powered on for normal operation:
輸入接點閉合時,紅色發(fā)光條9亮,表示接地開關處于合閘狀態(tài);
When the input contact is closed, the red light bar 9 will be on and it indicates that the earthing switch is under close position;
輸入接點斷開時,綠色發(fā)光條10亮,表示接地開關處于分閘狀態(tài)。
When the input contact is disconnected, the green light bar 10 will be on and it indicates that the earthing switch is under open position.
4)彈簧儲能指示
4) Spring energy storage instructions
將儲能機構的輔助接點正確接入裝置,裝置上電正常工作后,輸入接點閉合,指示燈13亮,表示已儲能。
After the auxiliary contact of energy storage mechanism is correctly connected in the device and the device is powered on for normal operation, the input contact will be closed and the indicator light 13 will be on and it indicates that energy has been stored.
注:開關量與指示燈對應關系可根據用戶需求靈活設定!
Note: The correspondence of switch quantity and indicator light can be flexibly set according to user needs.
3.2.3高壓帶電顯示及閉鎖
3.2.3 HV live displaying and lock
裝置的高壓帶電顯示功能適用于3.6-40.5kV/50Hz系統,與相應電壓等級的傳感器配合使用,顯示主回路的帶電情況。若傳感器為用戶自行配置,須保證其對地短路輸出電流大于200μA。
The HV live displaying function of device is Applicable to 3.6-40.5kV/50Hz system, which is used cooperatively with corresponding voltage classes to display the live condition of main circuit. If the sensor is allocated by the user itself, it must guarantee that the earthing short circuit output current shall be larger than 200μA.
在母線各相電壓均小于額定電壓的15%時,強制閉鎖處于“解鎖”狀態(tài),前面板上“LOCK”指示燈不亮,“閉鎖”接點閉合;母線任意相電壓大于額定電壓的40%時,強制閉鎖處于“閉鎖”狀態(tài),“LOCK”指示燈亮,“閉鎖”接點斷開。
When the voltage of all phases of busbar is less than 15% of rated voltage, the forced lock is under“unlock” status and the“LOCK” indicator light on front panel will not be on and the“Lock” contact will be closed; when any phase voltage of busbar is larger than 40% of rated voltage, the forced lock is under“lock” status and“LOCK” indicator light will be on, the“lock” contact will be disconnected.
3.2.4報警繼電器輸出
3.2.4 Alarm relay output
自動定值越限告警繼電器輸出包括:過壓、欠壓、過流、溫控1超溫、溫控2超溫、無線溫度傳感器組1高溫、無線溫度傳感器組2高溫、無線溫度傳感器組3高溫、無線溫度傳感器組4高溫。
The auto definite value threshold crossing alert relay output includes: overvoltage, undervoltage, over current, temperature control 1 over temperature, temperature control 2 over temperature, wireless temperature sensor group 1 high temperature, wireless temperature sensor group 4 high temperature.
注意:需將相應的控制字選擇為“投入”才有效!
Note: It is valid only corresponding control word is selected as“input”.
3.2.5自動溫濕度控制
3.2.5 Auto temperature and humidity control
采用數字式溫濕度控制,當環(huán)境相對濕度≥85%,啟動加熱,當相對濕度≤77%,停止加熱;當環(huán)境溫度≥40℃,啟動風扇鼓風,當溫度≤35℃,停止鼓風。當環(huán)境溫度≤5℃,啟動加熱,當環(huán)境溫度≥13℃,停止加熱。ASD500可測量并采用LCD顯示現場環(huán)境的溫度和濕度,帶有加熱、鼓風控制接點,可根據需要,自行設定加熱、除濕、鼓風的上下限。傳感器及其相關的參數及控制接點關系如圖2.2所示。
Digital temperature and humidity control.When the environment relative humidity is≥85%, start heating; when the relative humidity is≤77%, stop heating; when the environment temperature is≥40℃, start fan blast; when the temperature is≤35℃, stop blasting. When the environment temperature is≤5℃, start heating; when the environment temperature is≥13℃, stop heating.ASD500 can measure and adopt LCD to display the temperature and humidity of site environment. With heating, blast control contact, the upper and lower limit of heating, dehumidification and blast can be set according to requirements. The sensor and related parameters and the relationship between control contact are shown in Figure 2.2.

圖2.2 溫濕度控制關系
Figure 2.2 Temperature and humidity control relationship
3.2.6無線測溫
3.2.6 Wireless temperature measurement
ASD500可選無線測溫功能,裝置通過無線溫度接收器和各無線溫度傳感器直接進行溫度值的傳輸,并采用液晶顯示各無線溫度傳感器所測溫度。通過菜單可設置無線溫度傳感器組的高溫告警值,當測得溫度值超出設定值時,裝置報警繼電器輸出觸點閉合。
ASD500 optional wireless temperature measurement functions. The device can directly transmit temperature values through wireless temperature receiver and all wireless temperature sensors and adopt LCD to display the temperature measured by all wireless temperature sensors. Through menu, the high temperature alarm value of wireless temperature sensor can be set. When the measured temperature value exceeds the set value, the device alarm relay output contact will be closed.
ASD主體與無線溫度傳感器的配對及校準(出廠已完成此工作,請勿隨意進行此操作):
Matching and calibration of ASD main body and wireless temperature sensor:(Factory set, Do not change it at will):
1)ASD主體液晶操作進入“調試—>節(jié)溫設置”下的節(jié)溫設置菜單。
1) ASD main body LC operation enters the thermostat setting menu under“debugging --->thermostat .
2)輸入對應無線溫度傳感器ID進行綁定,如查看標簽為TA1的無線溫度傳感器的ID,將此ID輸入到節(jié)溫1A,輸入完全部要配對傳感器,按刷新鍵保存設置。
2)Enter the ID of the wireless temperature sensor corresponding to the wireless temperature sensor, such as the ID of the wireless temperature sensor with the tag TA1, enter this ID into the section temperature 1A, enter all the sensors to be matched, and press the refresh button to save the setting
3) ASD主體液晶操作進入“調試—>節(jié)溫校準”下的節(jié)溫校準菜單。
3) ASD main body LC operation enters the thermostat calibration menu under“debugging --->thermostat.
4)更改需校準的節(jié)溫值為準確值,按刷新鍵進行校準。
4)Change the section temperature to be calibrated to the exact value, press the refresh key to calibrate.
警告!出廠時包裝箱內無線溫度傳感器與ASD主體已配對和校準!安裝時不可以與其他ASD主體或無線溫度傳感器混用,無線溫度傳感器按其標簽A、B、C分別對應安裝到A、B、C相。
Warning! When it is delivered, the wireless temperature sensor in the packing case has already been matched with ASD main body and calibrated. When it is installed, it cannot be mixed with any other ASD main body or wireless temperature sensor. The wireless temperature sensor shall be respectively installed to A, B and C-phase according to its label A, B and C.
ASD主體與無線溫度傳感器可按以下方法進行配套識別:
The ASD body and the wireless temperature sensor can be identified in the following ways:


ATE200標簽
ATE200 Tag
ASD標簽 ATE400標簽
ASD Tag ATE400 Tag
例如左圖為一臺ASD主體的標簽,如果此ASD配套的傳感器為ATE100/ATE100M/ATE200/ATE400,則傳感器的標簽的“組號”和ASD主體條碼的最后3位數值一樣。
For example, the left image is a label of an ASD body; if the sensor associated with the ASD is the ATE100/ATE100M/ATE200/ATE400, the“Group No.” of the tag of the sensor is the same as the last 3-bit value of the ASD body barcode.
3.2.7智能語音防誤提示
3.2.7 Intelligent voice error-preventing prompt
智能語音防誤提示共有三種方式可選擇。
Three methods can be selected for intelligent voice error-preventing prompt.
方式一:斷路器、接地開關處于合閘狀態(tài),若誤將小車從試驗位置推至工作位置,裝置語音提示“請分斷路器,請分接地開關”;斷路器處于合閘狀態(tài),若誤將小車從試驗位置推至工作位置,裝置語音提示“請分斷路器”;接地開關處于合閘狀態(tài),若誤將小車從試驗位置推至工作位置,裝置語音提示“請分接地開關”。
Method I: When the breaker and earthing switch are under close position, if the trolley is pushed to operating position from testing position by mistake, the device voice will prompt“please disconnect the breaker and earthing switch”; when the breaker is under open position, if the trolley is pushed to operating position from testing position by mistake, the device voice will prompt“please disconnect the breaker”; when the earthing switch is under open position, if the trolley is pushed to operating position from testing position by mistake, the device will voice prompt“please disconnect the earthing switch”.
方式二:斷路器、接地開關處于合閘狀態(tài),若誤將小車從試驗位置/工作位置推開,裝置語音提示“請分斷路器,請分接地開關”;斷路器處于合閘狀態(tài),若誤將小車從試驗位置/工作位置推開,裝置語音提示“請分斷路器”;接地開關處于合閘狀態(tài),若誤將小車從試驗位置/工作位置推開,裝置語音提示“請分接地開關”。
Method II: When the breaker and earthing switch are under close position, if the trolley is pushed away from testing position/operating position by mistake, the device will voice prompt“please disconnect the breaker and earthing switch”; when the breaker is under close position, if the trolley is pushed away from testing position/operating position by mistake, the device will voice prompt“please disconnect the breaker”; when the earthing switch is under close position, if the trolley is pushed away from testing position/operating position by mistake, the device will voice prompt“please disconnect the earthing switch”.
方式三:斷路器處于合閘狀態(tài),若誤將小車從試驗位置/工作位置推開,裝置語音提示“請分斷路器”。
Method III: When the breaker is under close position, if the trolley is pushed away from testing position/operating position by mistake, the device will voice prompt“please disconnect the breaker”.
3.2.8柜內照明功能
3.2.8 Cabinet lighting function
在裝置參數菜單欄的動作界面,按至on,強制打開柜內照明,可修改照明時間;按至off,將關閉柜內照明。
Press the Up key under the default main interface of device to open the lighting in the cabinet; then press the Up key again to close the lighting in the cabinet.
3.2.9人體感應
3.2.9 Human body induction
LCD背光自動控制開啟(背光延時設置不為0),人離開裝置一段時間后,自動關閉柜內照明和液晶背光;當有人接近裝置時,裝置通過感應到周圍紅外場的變化感知有人接近,自動打開柜內照明及液晶背光。
LCD backlight auto control open (backlight delay shall not be set as 0): after leaving the device for a while, it will automatically close the lighting and LC backlight in the cabinet; when someone Approaches the device, the device will perceive that someone is Approaching through the change of surrounding infra-red field and automatically open the lighting and LC backlight in the cabinet.
3.2.10電力參數測量
3.2.10 Electric power parameter measurement
ASD500型開關柜綜合測控裝置可以測量主回路的電流、電壓、有功功率、功率因數、電能等電力參數,可在裝置“電量”菜單中查看。無功功率、視在功率等可以通過通訊口讀出。
ASD500 switch cabinet integrated measuring and control device can measure the current, voltage, active power, power factor, electric energy and other electric parameters of main circuit and check in the“electric quantity” menu of device. the active power, Apparent power can be read out through communication port.
電參數的顯示均為一次側值,用戶需選擇正確的信號接入方式及CT、PT變比,以便正確顯示測量值。
The display of electric parameter is all primary side value and the user shall select correct signal access way and CT, PT no-load voltage ratio to correctly display the measured value.
3.2.11帶電顯示自檢
3.2.11 Self-inspection of live displaying
ASD500開關柜綜合測控裝置具有帶電顯示自檢功能,可在裝置面板的下方按鍵進行自檢操作。按下按鈕,對應指示燈亮并保持幾秒鐘,閉鎖繼電器端子斷開(閉鎖繼電器端子不工作時處于常閉狀態(tài)),說明帶電顯示燈正常。
ASD500 switch cabinet integrated measuring and control device has live displaying self-inspection function, which can take self-inspection operation through the key under device panel. Press the button and corresponding LED will be lit for a few seconds and the lock relay will be open (it is normally closed when lock relay terminal is not working) and it indicates that the live displaying light is normal.
3.2.12核相功能
3.2.12 Nuclear phase function
ASD500開關柜綜合測控裝置具有帶電顯示核相功能,在裝置接入高壓信號經帶電顯示傳感器后的信號后,可通過外接核相器接入裝置的核相孔中,進行核相操作。該核相功能適用于市面上大多數的核相器(門檻電壓≥60V)。
ASD 500 switch cabinet integrated measuring and control device has live displaying nuclear phase function. After connecting the signal of live displaying sensor through HV signal, it can take nuclear phase operation by connecting the nuclear phase into the nuclear phase hole of device. This nuclear phase function is Applicable to great majority nuclear phase testers in the market (with threshold voltage≥60V).
注:本公司不配置核相器。
Note: Nuclear phase tester is not configured in our company.
1)上電后,裝置自檢,若自檢通過,點擊屏幕,進入電力參數顯示界面,可查看電流、電壓、功率、電能等各類電力參數(均為一次側值)。
1) After power on, take self-inspection to the device. If the self-inspection passes, click on the screen,enter electric parameter display interface and check the current, voltage, power, electric energy and various kinds of electric parameters (all primary side values) through left key (or right key) switching.
2)選擇“溫濕”菜單,即進入溫濕度控制信息顯示頁面,該頁面顯示通道1、通道2、和通道3所測得的環(huán)境溫度和濕度。
2) Select“temperature and humidity” menu to enter the temperature and humidity control information display interface, as shown in the figure below. This page display the environment temperature and humidity measured through channel 1 、channel 2 and channel 3 .
3)“參數”菜單可以設置裝置工作的各類參數,包括電流電壓信號的輸入方式、變比,各類報警閾值、控制字,通訊參數等。該菜單下的內容需要用戶口令才可以查看或修改,出廠設置口令為“0008”。
3) “Parameter” menu can set various kinds of operating parameters of device, including the input mode, no-load voltage ratio of current and voltage signal, various kinds of alarm threshold value, control word, communication parameters, etc. The content under the menu can be checked or modified only by user password. The factory set password is“0008”.
“定值”子菜單下可設置如電流電壓接線方式,變比報警閥值等(電參數告警定值均采用二次側值)。例如,過壓投退設置為“投入”,則當裝置測得的電壓值高于過壓定值時,報警繼電器輸出觸點閉合。
The current and voltage wiring mode and no-load voltage ratio alarm threshold value (electric parameter alarm definite values all adopt secondary side value) can be set under“definite value” submenu. For example, set the overvoltage in-service and out-of-service as“in-service”, when the measured voltage value of device is higher than the overvoltage definite value, the alarm rely output contact will be closed.
“狀態(tài)指示”子菜單下可設置LED燈與開入的對應關系,也可設置LED燈常亮(ON)或者是常滅(OFF)。
The correspondence of LED lamp and opening-in can be set under“status indicator” submenu and LED lamp can be set as normally on (ON) or normally off (OFF).
“通信”子菜單下可設置設備的通訊地址及串口波特率。
The communication address and series rate can be set under“communication” submenu.
“繼電控制”子菜單下可設置開出模式,模式分為:
Opening-out mode can be set under“relay control” submenu and the mode is classified into:
ON:設備上電后,繼電器常閉觸點為斷開,常開觸點為閉合(適用于手動控制)。
ON: After the device is powered on, the relay normally-closed contact will be disconnected and the normally-open contact will be closed (Applicable to manual control).
OFF:設備上電后,繼電器常閉觸點為閉合,常開觸點為斷開(適用于手動控制)。
OFF: After the device is powered on, the relay normally-closed contact will be closed and the normally-open contact will be disconnected (Applicable to manual control).
Def.:由內部邏輯控制繼電器的閉合或斷開。
Def: The interior logic will control the relay opening or closing.
“其它”子菜單下可進行“清電能”,“次數清零”和“恢復出廠”操作,出廠設置口令為“1008”。
“Clearing electric energy”,“Time reset” and“factory reset” operation can be taken under“others” submenu and the factory setting password is“1008”.
注意:
Note:
1、恢復出廠后,除電參量校準數據,無線溫度配對和校準數據外,其他所有參數都將恢復為出廠默認設置?;謴统鰪S后設備須重新上電后才生效!
1. After factory reset, except electric parameter calibration data, wireless temperature matching and calibration data, all the other parameters will be reset as factory default. After factory reset, the equipment must be powered on before it is effective.
2、電能清零后無法恢復,請謹慎使用此功能!
2. The electric energy will not be recovered after resetting, please be cautious to use this function!
“液晶背光”子菜單下可設置液晶背光點亮時長。
LC backlight lightening length can be set under“LC backlight” submenu.
注意:對有人體感應的裝置,該時間值也是人體感應控制照明輸出的時間。
Note: For device with human body induction, the time value is also the time that human body induction controls lighting output.
圖2.4接線方式
Figure 2.4 Wiring mode
4通訊指南
4 Communication guide
在本章主要講述如何利用軟件通過通訊口來操控該系列儀表。本章內容的掌握需要您具有MODBUS協議的知識儲備并且通讀了本冊其他章節(jié)所有內容,對本產品功能和應用概念有較全面的了解。
In this chapter, it mainly introduces how to use software to control this series of instrument through communication port. To master this chapter, you must possess the knowledge reserve of MODBUS and have read all the contents in other chapters and have comprehensive understanding to the function and Application concept of the product.
本章內容包括:通訊應用格式詳解,本機的應用細節(jié)及參量地址表。
The content of the chapter includes: detailed explanation of communication Application format, Application details and parameter address table.
4.1通訊格式詳解
4.1 Detailed explanation of communication format
本節(jié)所舉實例將盡可能的使用如下表所示的格式,數據為十六進制。
The format shown in table below will be used as much as possible for the examples in this section and the data is hexadecimal.
4.1.1讀取數據(功能碼03H/04H)
4.1.1 Reading data (function code 03H/04H)
此功能允許用戶獲得設備采集與記錄的數據及系統參數。主機一次請求的數據個數沒有限制,但不能超出定義的地址范圍。
The function allows user to obtain the data and system parameters collected and recorded by equipment. There is no restriction to the data number primarily requested by main engine, but it shall not exceed the defined address scope.
例如,主機發(fā)送查詢數據幀:
For example, main engine will send the query data frame:
地址
Addr
功能碼
Fun
起始地址
Start Addr
寄存器數量
Register number
CRC16校驗碼
CRC 16 check code
高 High
低Low
高High
低Low
高High
低Low
01H
03H
00H
30H
00H
03H
05H
C4H
裝置返回響應數據幀:
The device will return the response data frame:
地址
Addr
功能碼
Fun
字節(jié)數
byte
數據1
Date 1
數據2
Date 2
數據3
Date 3
CRC16校驗碼
CRC 16 check code
高
High
低Low
高
High
低
Low
高
High
低
Low
高
High
低
Low
01H
03H
06H
00H
00H
00H
00H
00H
00H
21H
75H
3.1.2預置單個寄存器(功能碼06H)
3.1.2 Preset single register (function code 06H)
此功能碼允許用戶改變單個寄存器的內容,可通過此功能碼將工作參數寫入裝置。
The function code allows user to change the content of single register and operating parameters can be written into device through the function code.
例如,主機發(fā)送:
For example, the main engine sends:
地址
Addr
功能碼
Fun
寄存器地址
Register address
預置值
Preset value
CRC16校驗碼
CRC 16 check code
高High
低 Low
高High
低Low
高High
低Low
01H
06H
00H
03H
03H
E8H
74H
79H
裝置返回響應數據幀:
The device returns to response data frame:
地址
Addr
功能碼
Fun
寄存器地址
Register address
預置值
Preset value
CRC16校驗碼
CRC 16 check code
高High
低 Low
高High
低Low
高High
低Low
01H
06H
00H
03H
03H
E8H
74H
79H
4.1.3預置多個寄存器(功能碼10H)
4.1.3 Preset several registers (function code 10H)
此功能碼允許用戶改變多個寄存器的內容,可通過此功能碼將工作參數寫入裝置。
The function code allows user to change the content of several registers and operating parameters can be written into device through the function code.
例如,主機發(fā)送:
For example, the main engine sends:
地址
Addr
功能碼
Fun
起始地址
Start Addr
寄存器數
Register number
字節(jié)數
byte
預置值1
Preset value 1
預置值2
Preset value 1
CRC16
高High
低Low
高High
低Low
高High
低Low
高High
低Low
高High
低Low
01H
10H
00H
03H
00H
02H
04H
00H
28H
00H
64H
59H
32H
裝置返回響應數據幀:
The device returns to response data frame:
地址
Addr
功能碼
Fun
起始地址
Start Addr
寄存器數量
Register number
CRC16校驗碼
CRC 16 check code
高字節(jié)
High byte
低字節(jié)
Low byte
高字節(jié)
High byte
低字節(jié)
Low byte
高字節(jié)
High byte
低字節(jié)
Low byte
01H
10H
00H
03H
00H
02H
B1H
C8H
4.2參量地址表
4.2 Parameter address table
地址
Addr
參數
Parameter
屬性
Read/Write
數值范圍
Data range
數據類型
Data Type
0000H
通訊地址
Communication Addr
R/W
1-247
Word
0001H
通訊波特率
Communication Baud rate
R/W
2400、4800、9600、19200
Word
0002H
電量輸入方式
Electric parameter
Input mode
R/W
0:3P3L 1:3P4L
Word
0003H
電流變比
CT transformation
R/W
0.1~999.9(x10)
Word
0004H
電壓變比
PT transformation ratio
R/W
0.1~999.9(x10)
Word
0005H
控制字
Control word
R/W
繼電器報警控制字: 0-off 1-on bit0:過壓 bit1:欠壓 bit2:過載 bit3-溫濕控1 bit4-溫濕控2 bit5:語音提示 bit8~bit11節(jié)溫組1~4bit12:分合閘電壓檢測開啟
Alarm relay control word:0-off,1-on
bit0:Over voltage;bit1:under voltage;bit2:over load;bit3-Temp./humidity control 1; bit4-Temp./humidity control 2;
bit5:Voice alert;
bit8~bit11:The section temperature group 1to4;
bit12: tripping circuit and closing circuit control voltage measurement function enabled.
Word
0006H
通道A低溫設定值
(加熱I)
Channel A Lo.temp.setting (heating I)
R/W
-45~125℃
Word
0007H
通道A高溫設定值
(鼓風)
Channel A Hi.temp.setting(air blowing)
R/W
0~125℃
Word
0008H
通道A超溫設定值(告警)
Channel A over-temp setting(alarm)
R/W
0~125℃
Word
0009H
通道A高濕度設定值(加熱I)
Channel A Hi humidity setting(heating I)
R/W
10~99%
Word
000AH
通道B低溫設定值(加熱II)
Channel B Lo.temp. setting(heating II)
R/W
-45~125℃
Word
000BH
通道B高溫設定值
(鼓風)
Channel B Hi.temp.setting(air blowing)
R/W
0~125℃
Word
000CH
通道B超溫設定值(告警)
Channel B over-temp setting(alarm)
R/W
0~125℃
Word
000DH
通道B高溫設定值(加熱II)
Channel B Hi.temp.setting
(heating II)
R/W
10~99%
Word
000EH
過壓定值
Overvoltage setting
R/W
二次側 1~999V
Secondary side 1~999V
Word
000FH
欠壓定值
Undervoltage setting
R/W
二次側 1~999V
Secondary side 1~999V
Word
0010H
過流定值
Overcurrent setting
R/W
二次側 0~99.9A(x10)
Secondary side 0~99.9A(x10)
Word
0011H
液晶背光自動關閉時間
Liquid crystal back light Automatic closed time
R/W
0-999s,0—背光常亮
0-999s,0:Always bright backlight
Word
0012H
繼電器輸出
Relay output
R/W
bit0-4對應:
加熱I、加熱II、鼓風、告警、照明
Bit0-bit4:
Heating I,heating II,air blowing,alarming,lighting
Word
0013H
開關量輸入
Switching input
R
Bit0-bit7對應DI1-DI8
Bit0-bit7 corresponding DI1-DI8
Word
0014H
定值類報警狀態(tài)
Value class alarm status
R
0-未告警 1-告警 bit0-bit3對應:通道A低溫、通道A高溫、通道A超溫、通道A高濕
bit4-bit7對應:通道B低溫、通道B高溫、通道B超溫、通道B高濕
bit8:過壓 bit9:欠壓 bit10:過載bit11-bit12對應:第一路測溫故障、第二路測溫故障
bit13-bit14對應:第一路加熱器故障第二路加熱器故障
0-no alarm,1-alarmed.
Bit0-bit3 corresponding: Channel A Lo.temp,Channel A Hi.temp,Channel A over temp,Channel A Hi humidity
Bit4-bit7 corresponding: Channel B Lo.temp,Channel B Hi.temp,Channel B over temp,Channel B Hi humidity
Bit8:over voltage;Bit9:under voltage;
Bit10:over load
Bit11-bit12 corresponding: 1nd temperature sensor failure, 2nd temperature sensor failure
Bit13-bit14 corresponding: 1nd heating circuit
fault alarm, 2nd heating circuitfault alarm
Word
0015H
無線溫度傳感器高溫報警狀態(tài)
Wirless temperature sensor Hi.temp. alarm status
R
0:未報警1:已報警
bit0~bit11:節(jié)點1A~4C高溫
0-no alarm,1-alarmed.
Bit0-bit 11 :
Section temperature 1A~ Section temperature 4C sensor Hi.temp.
Word
0016H
無線溫度傳感器低電壓報警狀態(tài)
Wirless temperature sensor low voltage alarm status
R
0:未報警1:已報警
bit0~bit11:節(jié)點1A~4C傳感器低電壓
0-no alarm,1-alarmed.
Bit0-bit 11 :
Section temperature 1A~ Section temperature 4C sensor low voltage.
Word
0017H
語音防誤提示方式
Wrong voice prompts
R/W
1~2
Word
0018H
年份
Year
R/W
10~99(對應2010~2099)
10~99 corresponding: 2010~2099
Word
0019H
月份
Month
R/W
1~12
Word
001AH
高位:日
High:Day
R/W
1~31
Word
低位:時
Low:Hour
R/W
0~23
Word
001BH
高位:分
High:Minute
R/W
0~59
Word
低位:秒
Low:Second
R/W
0~59
Word
001CH
無線溫度傳感器組1高溫定值
Wireless temperature sensor group 1 high temperature setting
R/W
0~125℃
Word
001DH
無線溫度傳感器組2高溫定值
Wireless temperature sensor group 2 high temperature setting
R/W
0~125℃
Word
001EH
無線溫度傳感器組3高溫定值
Wireless temperature sensor group 3 high temperature setting
R/W
0~125℃
Word
001FH
無線溫度傳感器組4高溫定值
Wireless temperature sensor group 4 high temperature setting
R/W
0~125℃
Word
0020~0022H
1A 1B 1C溫度值
1A 1B 1C temperature value
R
0~125.0℃(x10)
Word
0023~0025H
2A 2B 2C溫度值
2A 2B 2C temperature value
R
0~125.0℃(x10)
Word
0026~0028H
3A 3B 3C溫度值
3A 3B 3C temperature value
R
0~125.0℃(x10)
Word
0029~002BH
4A 4B 4C溫度值
4A 4B 4C temperature value
R
0~125.0℃(x10)
Word
002CH
通道A溫度值
Channel A
temperature value
R
-45.0~125.0℃(x10)
Word
002DH
通道A濕度值
Channel A
humidity value
R
10.0~99.0%(x10)
Word
002EH
通道B溫度值
Channel B
temperature value
R
-45.0~125.0℃(x10)
Word
002FH
通道B濕度值
Channel B
humidity value
R
10.0~99.0%(x10)
Word
0030H
相電壓UA
Phase voltage UA
R
一次側:0~6553.5 kV(x10)
Primary side: 0~6553.5 kV(x10)
Word
0031H
相電壓UB
Phase voltage UB
R
一次側:0~6553.5 kV(x10)
Primary side: 0~6553.5 kV(x10)
Word
0032H
相電壓UC
Phase voltage UC
R
一次側:0~6553.5 kV(x10)
Primary side:
Word
0033H
線電壓UAB
Line voltage UAB
R
一次側:0~6553.5 kV(x10)
Primary side: 0~6553.5 kV(x10)
Word
0034H
線電壓UBC
Line voltage UBC
R
一次側:0~6553.5 kV(x10)
Primary side: 0~6553.5 kV(x10)
Word
0035H
線電壓UAC
Line voltage UAC
R
一次側:0~6553.5 kV(x10)
Primary side: 0~6553.5 kV(x10)
Word
0036H
IA
R
一次側:0~6553.5 A(x10)
Primary side: 0~6553.5 kV(x10)
Word
0037H
IB
R
一次側:0~6553.5 A(x10)
Primary side: 0~6553.5 kV(x10)
Word
0038H
IC
R
一次側:0~6553.5 A(x10)
Primary side: 0~6553.5 kV(x10)
Word
0039H
保留
Reserved
R
保留
Reserved
003AH-003BH
PA
R
一次側:0~6553.5kW
Primary side: 0~6553.5kW
float
003CH-003DH
PB
R
一次側:0~6553.5kW
Primary side: 0~6553.5kW
float
003EH-003FH
PC
R
一次側:0~6553.5kW
Primary side: 0~6553.5kW
float
0040H-0041H
Psum
R
一次側:0~6553.5kW
Primary side: 0~6553.5kW
float
0042H-0043H
QA
R
一次側:0~6553.5kvar
Primary side: 0~6553.5kvar
float
0044H-0045H
QB
R
一次側:0~6553.5kvar
Primary side: 0~6553.5kvar
float
0046H-0047H
QC
R
一次側:0~6553.5kvar
Primary side: 0~6553.5kvar
float
0048H-0049H
Qsum
R
一次側:0~6553.5kvar
Primary side: 0~6553.5kvar
float
004AH-004BH
PFA
R
0.0~1.0
float
004CH-004DH
PFB
R
0.0~1.0
float
004EH-004FH
PFC
R
0.0~1.0
float
0050H-0051H
Pfsum
R
0.0~1.0
float
0052H-0053H
SA
R
一次側:0~6553.5kVA
Primary side: 0~6553.5kVA
float
0054H-0055H
SB
R
一次側:0~6553.5kVA
Primary side: 0~6553.5kVA
float
0056H-0057H
SC
R
一次側:0~6553.5kVA
Primary side: 0~6553.5kVA
float
0058H-0059H
Ssum
R
一次側:0~6553.5kVA
Primary side: 0~6553.5kVA
float
005AH-005BH
Freq
R
45.0~65.0Hz
float
005CH-005DH
電能
Electrical energy
R
一次側:0.0~99999999.99kWh
Primary side: 0.0~99999999.99kWh
float
005EH
產品類型
Product Type
R/W
0~5對應:100、100G、200、300、310、320
Word
005FH
通道A低溫報警返回值設定
Low temperature alarm return value of Channel A
R/W
-45~125℃
Word
0060H
通道A高溫報警返回High temperature alarm return value of Channel A
R/W
0~125℃
Word
0061H
通道A超溫報警返回值設定
Over temperature alarm return value of Channel A
R/W
0~125℃
Word
0062H
通道A高濕報警返回值設定
High humidity alarm return value of Channel A
R/W
10~99%
Word
0063H
通道B低溫報警返回值設定
Low temperature alarm return value of Channel B
R/W
-45~125℃
Word
0064H
通道B高溫報警返回值設定
High temperature alarm return value of Channel B
R/W
0~125℃
Word
0065H
通道B超溫報警返回值設定
Over temperature alarm return value of Channel B
R/W
0~125℃
Word
0066H
通道B高濕報警返回值設定
High humidity alarm return value of Channel B
R/W
10~99%
Word
0067H
繼電器告警延遲時間
Alarm delay
R/W
1.0-20.0 s(*10)
Word
0068H-0069H
——
R/W
——
006AH
強制加熱時間
Manual heating time
R/W
0~120min 0:不加熱
0~120min 0:Manual heating not performed
6BH~199H
保留
Reserved
保留
Reserved
200H
工作語言:
Language:
R/W
0:中文1:英文
0:Chine 1:English
Word
201H
密碼1
Password 1
R/W
0-9999
Word
202H
密碼2
Password 2
R/W
0-9999
Word
203H
輪詢時間
Polling time
R/W
0~9999s 0:不輪詢
0~9999s 0:no poll
Word
204H
通訊數據位
Communication data bits
R/W
8~9
Word
205H
通訊停止位
Communication stop bit
R/W
0~2:0:1停止位1:1.5停止位2:2停止位
0~2:0:1 stop bit 1:1.5 stop bit 2:2 stop bit
Word
206H
通訊奇偶校驗位
parity checkbit
R/W
0~2:0:無奇偶校驗1:奇校驗2:偶校驗
0~2:0:No parity 1:Odd parity 2:Even parity
Word
207H
無線通訊波特率
Wireless baud rate
R/W
2400、4800、9600、19200
Word
208H
無線通訊數據位
Wireless communication data bit
R/W
8~9
Word
209H
無線通訊停止位
Wireless communication stop bit
R/W
0~2:0:1停止位1:1.5停止位2:2停止位
0~2:0:1 stop bit 1:1.5 stop bit 2:2 stop bit
Word
20AH
無線通訊奇偶校驗位
Wireless communication parity check bit
R/W
0~2:0:無奇偶校驗1:奇校驗2:偶校驗
0~2:0:No parity 1:Odd parity 2:Even parity
Word
20BH
無線測溫傳感器組1返回值
return value ofWireless temperature sensor group 1
R/W
0~125℃
Word
20CH
無線測溫傳感器組2返回值
return value ofWireless temperature sensor group 2
R/W
0~125℃
Word
20DH
無線測溫傳感器組3返回值
return value ofWireless temperature sensor group 3
R/W
0~125℃
Word
20EH
無線測溫傳感器組4返回值
return value ofWireless temperature sensor group 4
R/W
0~125℃
Word
20FH
DO1工作模式
DO1 output mode
R/W
0:off 1:on 2:def.:normal
Word
210H
DO2工作模式
DO2output mode
R/W
0:off 1:on 2:def.:normal
Word
211H
DO3工作模式
DO3output mode
R/W
0:off 1:on 2:def.:normal
Word
212H
DO4工作模式
DO4output mode
R/W
0:off 1:on 2:def.:normal
Word
213H
DO5工作模式
DO5output mode
R/W
0:off 1:on 2:def:normal
Word
214H
DO6工作模式
DO6output mode
R/W
0:off 1:on 2:def.:normal
Word
215H
合閘LED燈配置
CB On LED configuration
R/W
0~24:對應1~25號燈
0~24 corresponding:1 ~ 25 lights
Word
216H
語音音量
Voice volume
R/W
0-7
Word
217H-21AH
保留
Reserved
R/W
保留
Reserved
Word
21BH
合閘電壓
closing circuit control voltage
R
0-6553.5V(*10)
Word
21CH
分閘電壓
tripping circuitcontrol voltage
R
0-6553.5V(*10)
Word
21DH
斷路器分合次數
CB tripping and closing numbers
R
0~65535
Word
21EH
分合閘電壓報警
Tripping/closing control voltage alarm
R
1:分閘過壓 2:合閘過壓
1: over voltage alarm of tripping control voltage 2: over voltage alarm of closing control voltage
Word
21FH
無線測溫傳感器類型Wireless temperature sensor type
R
0:ATE100 1:ATE300 0xff:未檢測到傳感器
0:ATE100 1:ATE300 0xff:wireless sensor offline
Word
220H~22BH
外部無線測溫傳感器的ID號
ID of wireless temperature sensor
R
0~FFFF:
有ID號:檢測到外部存在,但未綁定的ID號
0xFFFF:未檢測到綁定的ID號
0~FFFF:
With ID number:An externally detected but unbound ID number
0xFFFF:No bound ID number detected
Word
22CH~237H
無線測溫傳感器狀態(tài)
Wireless temperature sensor status
R
0~0xFFFF
有ID號:已檢測到節(jié)點對應ID號存在
0xFFFF:未檢測到節(jié)點對應ID號存在
0~0xFFFF
ID is detected:the sensor of the detected ID is online
0xFFFF:the sensor is offline
Word
注:[1] R—只讀;R/W—可讀,可寫。
[2]×10,×100,×1000—讀取時實際值乘以相應的倍數上傳,寫入時應乘以相應的倍數寫入。
Note: [1] R-Read only; R/W-Readable, writable.
[2] ×10, ×100, ×1000-When reading, upload with practical value multiply corresponding times; when writing, write in by multiplying corresponding times.
5常見故障的診斷分析與排除方法
5Diagnostic analysis and troubleshooting of common faults
5.1輔助電源故障
5.1 Fault of auxiliary power supply
裝置接通輔助電源后屏幕不亮?
The screen does not light after connecting the auxiliary power supply.
可能原因:外接端子線序錯誤。
Possible cause: the external terminal line sequence is wrong.
處理方法:拔出“溫濕度I”,“溫濕度II”,“無線測溫”接口處的外接模塊,重新上電裝置判斷。
Handling method: pull out the external module at the joint of“temperature and humidity I”,“temperature and humidity II”,“wireless temperature measuring” and re-power on to judge.
5.2環(huán)境溫濕度顯示故障
5.2 Fault of environment temperature and humidity display
溫濕菜單下環(huán)境溫濕度值無顯示或顯示“rupt”?
The environment and humidity value under temperature and humidity menu has no display or displays“rupt”?
可能原因:溫濕度控制字未投入或溫濕度模塊未接好。
Possible cause: The temperature and humidity control word is not input or temperature and humidity module is not well connected.
處理方法:
Handling method:
1)無顯示時:“參數->定值”菜單將“溫濕1投退”或“溫濕2投退”或“溫濕3投退”設置為投入。
1)When there is no display:“parameter -->definite value” menu will set the“temperature and humidity 1 out-of-service” or“temperature and humidity 2 out-of-service”or“temperature and humidity 3 out-of-service” as in-service.
2)顯示“rupt”時:檢查“溫濕度I”,“溫濕度II”接口處的溫濕度模塊接入是否正確?
2) When displaying“rupt”: check whether the temperature and humidity module is correctly connected at the joint of“temperature and humidity I”,“temperature and humidity II”.
5.3告警繼電器動作故障
5.3 Fault of alarm relay operation
欠壓,過壓,過流,環(huán)境溫度超溫,無線節(jié)點溫度高溫定值越限而告警繼電器不動作?
Undervoltage, overvoltage, environment temperature exceeds, wireless node high temperature definite value is out-of-limit and alarm relay does not work.
可能原因:相應的控制字未投入。
Possible cause: corresponding control word is not input.
處理方法:“參數->定值”菜單將相應的控制字設置為投入。
Handling method:“Parameter-->” menu should set corresponding control word as input.
5.4一次模擬狀態(tài)指示燈故障
5.4 Fault of primary simulated status indicator light
開關量輸入與狀態(tài)指示燈不對應或狀態(tài)指示燈不亮?
Switch input and status indicator light is not corresponding or status indicator light is not on.
可能原因:狀態(tài)指示燈設置錯誤。
Possible cause: status indicator light setting is wrong.
處理方法:“參數->狀態(tài)指示”設置狀態(tài)指示燈對應的開關量,如需常亮的設置為“ON”,未使用的設置為“OFF”。
Handling method:“Parameter--> status indicator” should set corresponding switch quantity of status indicator light. For example, if it needs normally on, set it as“ON”; if it is not used, set it as“OFF”.
5.5通信故障
5.5 Communication fault
上位機或后臺軟件與裝置通信錯誤?
There is something wrong with communication between upper computer or background software with device.
可能原因:裝置地址或串口參數設置錯誤。
Possible cause: Device address or serial port parameter setting is wrong.
處理方法:“參數->通信”設置正確的裝置地址或串口參數。
Handling method:“Parameter--> communication” should set correct device address or serial port parameters.
5.6節(jié)點溫度值顯示故障
5.6 Fault of node temperature value display
ASD主體“節(jié)溫”菜單無溫度值顯示或無某一路溫度值顯示?
ASD main body“thermostat” menu has no temperature value display or no temperature value display of some path.
可能原因:電池開關未打開或傳感器不配對。
Possible cause: battery switch is not opened or sensor is mismatched.
處理方法:
Handling method:
1)查看無線溫度傳感器的電池開關是否撥到“ON”端?(電池開關從OFF端撥到ON端后,無線溫度傳感器上的綠燈亮滅閃爍2次表示開關接通正常,否則重復撥動)。
1) Check whether the battery switch of wireless temperature sensor is dailed to“ON” terminal (after battery switch is dialed to ON terminal from OFF terminal, the green light on wireless temperature sensor will flicker twice and it means that the switch is connected normally; otherwise, re-dial it0.
2)查看ASD主體上的條碼與無線溫度傳感器上的條碼是否一致,不一致時找到對應的無線溫度傳感器更換或重新配對無線溫度傳感器(詳見本說明書2.2.6章節(jié)下的“ASD主體與無線溫度傳感器的配對及校準”部分)。
2) Check whether the code on ASD main body and wireless temperature sensor is consistent. When it is inconsistent, find out corresponding wireless temperature sensor to replace or rematch wireless temperature sensor (See“Matching and calibration of ASD main body and wireless temperature sensor” part under Section 2.2.6 of the specification).
附A LW42凸輪開關安裝說明
Annex A Installation instructions of LW42 cam switch


注:詳細說明請到上海天逸電器股份有限公司官網:http://www.tayee.com.cn下載相應的文檔查看。
Note: For detailed specification, please go to Shanghai Tayee Electrical Co., Ltd. official website: http://www.tayee.com.cn to download corresponding documents.
附B儲能開關安裝說明
Annex B Installation specification of stored energy switch